X ray tube (Higashibara,Japan) | Type | Closed, micro-spots |
Tube voltage | 90KV | |
Tube current | 200μA | |
Size of the spot | 5μm-15μm | |
Maximum input power | 8W | |
X-ray beam angle (cone) | 80 degree | |
Amplified factor | The geometric magnification is 150 times and the system magnification is 1500 times | |
Flat panel detector (Yi Rui) | Type of probe | Amorphous silicon flat panel detector |
Image area | 130mm×130mm | |
Size of photosensitive unit | 85μm | |
Pixel matrix | 1536×1536 | |
The tilt Angle of the probe | 0-90° Angle (45° on each side) | |
Resolution ratio | 5.8Lp/mm | |
Image frame rate (1x1) | 20fps | |
Software | Function | Bubble measurement, size measurement, batch testing or other custom functions |
Intellectual property right | Independent research and development, with independent intellectual property rights of software | |
Shielded cell | Material quality | Steel + lead + steel plate, sandwich structure shielding box, effective isolation of radiation |
Safety | The radiation dose equivalent rate <0.5μSV/H is higher than the international standard. | |
Size | L1500mm *W1300mm* H1800mm | |
Weight | About 1500Kg | |
Insurance | Safety interlock function | When the safety door is opened, the light tube cannot be opened. When the light tube is opened, the automatic lock is locked and the safety door is closed. |
Electromagnetic switch protection function | The observation window is equipped with an electromagnetic switch. When the X-ray tube is in working condition, the observation window cannot be opened. | |
Visible window | It has a visible transparent window, which makes it easy to observe the sample directly from the window during the operation of the equipment. | |
Emergency stop switch | The emergency stop switch is located in a prominent position on the operation table and equipment body. In case of emergency, press the emergency stop switch to quickly cut off power. | |
Automatic protection function of light pipe | After 5 minutes without any operation, the light tube will automatically cut off power and enter the protection state. | |
Radiation safety standards | The steel-lead-steel protective structure is independently produced, and the front door window is made of lead glass. At any position of 20mm of the equipment. | |
The tested radiation amount is less than 0.5μSV/H, and higher than the international standard is less than 1μSV/H. | ||
Automatic protection function of the equipment | Once any door or window of the equipment is opened, it will immediately close the light tube and enter the shutdown protection state. |